Brand NEW Diesel Generator For Sale

METCL diesel generator repair and maintenance service

I hope you enjoy reading this generator blog post.

If you need , click here.

Perkins 403A-15G2 12kw diesel generator fuel consumption

Perkins 12kW diesel generator Fuel Consumption

The Perkins 12kW diesel generator is powered by a Perkins engine 403A-15G2. It has a special enclosure to reduce noise in any weather, keeping it at 65db at a 7m distance. It also has a built-in fuel tank so you don't have to refuel often, using less than 3.3L/h of fuel consumption. An AVR guarantees stable power and has safety features like automatic shutdown for low oil levels or other problems.

POWER OUTPUT:

13.2KW (16.5KVA) STANDBY, 12.0KW (15.0KVA) PRIME, 3PHASE, 0.8PF, 50HZ

 

METCL Perkins 403A-15G2 12KW 15KVA diesel generator

Datasheet of Perkins 12kW Diesel Generator

  • Genset Supplier - METCL
  • Genset Model - P16GFS
  • Generator Speed - 1500 RPM
  • Displacement - 1.496 Litre
  • Fuel Consumption at rated 12kW/15KVA Load- 3.3 Litre/h
  • Kubota Engine 403A-15G2, 15.2kW, 1500RPM, Turbocharged
  • Electronic Speed Governor
  • Radiator cooling system with fan guards and coolant drain extension with in-line valve
  • AC Alternator Producer - STAMFORD/Leroy-Somer/Mecc Alte
  • AC Alternator 4 Leads, brushless, 100% Copper Windings
  • Full load rated Power - 12kW/15kVA
  • 50 Hz. 1500RPM 3Phase AC400V
  • 3-Phase AC380/415/440V etc Multi-voltage as optional
Features of Perkins Engine 403A-15G2
  • The 403A-15G2 ElectropaK is a powerful but quiet 1.5 litre naturally aspirated 3-cylinder compact package
  • Design features on the 400D range of ElectropaKs ensure clean rapid starting in all conditions whilst delivering impressive performance with low operating costs in a small, efficient package size
  • Approved for operation on biodiesel* concentrations of up to 20%
  • Oil and filter changes are 500 hours, dependent on the load factor
  • Engine durability and reliability, the warranty offering, and ease of installation combine to drive down the cost of
    ownership
  • Perkins Engine provides one-year warranties for constant-speed engines and two-year warranties for variable-speed models, as standard.

Perkins 12kW diesel generator Fuel Consumption

Perkins engine 403A-15G2 12KW diesel generator fuel consumption

GENERAL PERKINS ENGINE 403A-15G2 DATA SHEET 
Air Inlet

  • Mounted air filter

Fuel System

  • Mechanically governed cassette-type fuel injection pump
  • Split element fuel filter

Lubrication System

  • Wet steel sump with filler and dipstick
  • Spin-on full-flow lube oil filter

Cooling system

  • The thermostatically-controlled system with a belt-driven coolant pump and pusher fan
  • Mounted radiator, piping, and guards

Electrical equipment

  • 12 volt starter motor and 12 volt 15 amp alternator with DC output
  • Oil pressure and coolant temperature switches
  • 12-volt shut-off solenoid energized to run
  • Glow plug cold start aid and heater/starter switch

Flywheel and housing

  • 1500 rev/min
  • High inertia flywheel to SAE J620 Size 190.5 mm (7½ in) Heavy
  • Flywheel housing SAE 4 Long

Mountings

  • Front and rear engine mounting bracket

Optional equipment

  • Parts book

Option groups

  • A selection of optional items is available to enable you to prepare a specification precisely matched to your needs